PW6-A Series Cabinet Air Conditioner
Keywords:
Keywords:
PW6-A Series Cabinet Air Conditioner
Category:
Tel:
PW6-A Series Cabinet Air Conditioner
Product Features
1 Brand refrigeration components combined with excellent airflow circuit design for stronger cooling
2 Excellent condensate isolation design ensures safe operation of internal components
3 The entire series uses R134a environmentally friendly refrigerants to reduce environmental pollution and meet international environmental standards
4 Extended distance design of inner circulation inlet and outlet ports ensures good air circulation within the cabinet, avoiding short-circuiting of the cold air circuit and improving cooling efficiency
5 Extended distance design and opposite wind direction design of outer circulation inlet and outlet ports avoid short-circuiting of the hot air circuit, improving heat exchange efficiency
6 Inner circulation uses a large airflow, small vent design for a longer heat dissipation distance
7 The entire series AC200-240V 50/60HZ Universal, meeting the needs of most power grids worldwide. 1500W The above models provide 400V optional power supply models
8 Ultra-thin design, minimum thickness 145mm both aesthetically pleasing and space-saving
9 Wide fin spacing design of the condenser extends the maintenance cycle
10 Double filtration with filter net and filter cotton, quick replacement, different density filter cotton can be selected according to air cleanliness, or only the filter can be used
11 Built-in intelligent condensate evaporator (optional), energy-efficient
12 Can be customized, including color, size, and material
13 The entire series has passed CE certification
Appearance Design
The overall design adopts a slender design concept, maximizing the distance between the inlet and outlet ports to extend the refrigeration path and prevent the formation of high-temperature dead zones inside the cabinet. The outer circulation inlet and outlet ports face in opposite directions, and the inner circulation inlet and outlet ports have an extra-long distance design to prevent airflow short-circuiting and reduce cooling efficiency. Minimum thickness 195mm Ultra-thin design, outer circulation air intake ports use a detachable filter; a filter net and filter cotton can be installed depending on the usage environment.
Safety
1、 Unique cold air duct design and condensate water channel design, condensate water 100% flows out from the drain pipe , ensures safe operation of electrical components inside the cabinet. A built-in
energy-saving electronic condensate evaporator can be selected. The electronic condensate evaporator can automatically adjust the evaporation temperature according to the water volume, eliminating the need for a water level switch, and increasing reliability
even further.
2. A miniature circuit breaker is designed as the air conditioner power switch, which has short-circuit and overcurrent protection functions, making debugging and maintenance safer and more convenient.
Product Functions
1、 Refrigeration: When the cabinet temperature is higher than the set temperature range, the refrigeration system works; when the cabinet temperature is lower than the set temperature range, the refrigeration system stops
working.
2、 Dehumidification: The cabinet air conditioner automatically dehumidifies the air inside the cabinet during operation.
3、 Auxiliary heating (optional): When the cabinet temperature is lower than the heating start temperature, the auxiliary heating system starts working; when the cabinet temperature is higher than the heating start temperature, the auxiliary heating
system stops working.
4、 Air circulation: The inner circulation system fan is always running after being powered on, so that the cabinet temperature can be kept uniform even when the refrigeration system is not working.
Built-in condensate evaporator (optional): An optional built-in energy-saving condensate evaporator can be used to automatically evaporate the condensate from the inner circulation.
5、 Communication (optional): Optional
6、 communication function for remote control via a host computer. RS485 Alarm output: The refrigeration system provides a passive contact alarm, and the contact operates when a system fault occurs.
7、 Auto-start:
8、 The series cabinet air conditioners start automatically when power is supplied. PW6-A Installation Method
The series cabinet air conditioners are wall-mounted and can be installed on the side or door panel of the cabinet.
1、PW6-A The series cabinet air conditioners only support vertical installation; the tilt angle should not exceed
2、PW6-A °, and they cannot be inverted, tilted, or installed horizontally. 2 The distance between the cabinet air conditioner panel and the wall or other cabinet air conditioner panels should be greater than
3 To ensure uniform cooling, the distance between the cabinet air conditioner outlet and the internal components should be no less than 200mm。
4 To reduce condensate generation, it is recommended to use it with a door limit switch. 200mm。
5 Quality Assurance
The warranty period for the series cabinet air conditioners is :PW6-A months. Free return-to-factory repair or replacement services are provided during the warranty period. 18 Standards
1. GB 4208
Enclosure protection grade GB4706.1
2、 Safety of household and similar electrical appliances GB 9237-2001
3、 Safety requirements for mechanical refrigeration systems for refrigeration and heating GB/T17626.8
4、 Electromagnetic compatibility test GB/T 4798.1
5、GB/T 4798.1、2、3 Application Environmental Conditions for Electrical and Electronic Products
6、EN55014-1:2017
7、EN55014-2:2015
8、EN61000-3-2:2014
9、EN61000-3-3:2013
Instructions for Use
1、 The rated cooling capacity of this series of products is L35/L35 Cooling capacity under conditions, when the ambient temperature exceeds 35 ℃, derating is required
2、 If the selected cooling capacity of the air conditioner is too small, it will lead to poor heat dissipation of the electrical cabinet, and in severe cases, it will cause damage to the air conditioner.
3、 This series of products is not suitable for occasions with heavy oil stains and dust, nor is it suitable for occasions with corrosive gases.
4、 When using this series of waterless products, if the condensate exceeds the evaporation capacity of the built-in condensate evaporator, the excess water will be discharged from the overflow port. To reduce condensate generation, please try to improve the sealing level of the electrical cabinet.
5、 If the installation density of the components in the cabinet is high, it will reduce the heat dissipation efficiency of the air conditioner. If necessary, it is necessary to reduce the installation density of the components or add an internal circulation fan.
6、 This series of products is a vertical wall-mounted air conditioner. It must be stored and used vertically. Inversion is prohibited. If it is not stored vertically, it must be straightened for 24 hours before power can be applied.
7、 When transporting this series of products, please ensure that they are kept upright. Transportation in a non-upright state may increase the possibility of air conditioner damage.
8、 The inlet and outlet vents of this series of products cannot be blocked. If blocked, it will lead to poor cooling effect, increased air conditioner failure rate, etc., and in severe cases, it will cause damage to the air conditioner.
9、 The external circulation air inlet of this series of products is equipped with a filter screen. The cleaning cycle can be determined according to the cleanliness of the environment. In principle, it should be cleaned at least once a month. In environments with very little dust, the filter screen can be removed.
|
Model |
Order Number |
|
PW605 |
601002 |
|
PW608 |
601004 |
|
PW615 |
601007 |
|
PW625 |
601009 |
Previous Page
None
Next Page
Online Consultation
Please leave your contact information, our professionals will contact you as soon as possible!